Investigators from the U.S. Chemical Safety Board and Hazard Investigation Board released an update Thursday that offers new ...
"We have seen this kind of incident before, and it often is because of a decomposition chemical reaction inside of the vessel ...
The U.S. Chemical Safety Board has released its final report on the explosion at Louisville's Givaudan facility that killed ...
"The employees were doing everything they were supposed to... it was the equipment that malfunctioned, which means it's ...
What caused Givaudan plant explosion in Louisville explained by U.S. Chemical Safety Board DOGE cost-cutter-in-chief Elon ...
According to the board's latest report, released Thursday, problems at the plant started around 2 p.m. Nov. 12, the day of the explosion.
The CSB found the reactor vessel’s automated vent valve was almost fully closed after the blast. The valve is supposed to ...
An ongoing investigation by the U.S. Chemical Safety Board (CSB) finds that in just 16 minutes, the container exploded. The ...
A public meeting Tuesday night will address the aftermath of the November explosion at Givaudan Color Sense in Clifton.
CSB investigators discovered the reactor vessel's automated vent valve was almost completely closed, and that it was designed to open so it could relieve pressure and maintain the setpoint.
A new report reveals that the pressure and temperature inside a vessel at the Givaudan Sense Colour factory far exceeded safety limits. The explosion killed two workers and scattered debris ...